
Cisco ASR 903 Series Router
-
$27,05067
$27,050.67
Unit price/ per
ASR-903
- SP AR HW 24X7X4 ASR 903 Series Router Chassis
- ASR 903 Metro Aggregation Services
- SP AR HW 24X7X4 ASR 903 Metro Aggregation Services
- Cisco ASR900 RSP3 IOS XE UNIVERSAL - PAYLOAD ENCRYPTION
- ASR 900 USB Console Cabling Kit
- ASR 900 Interface Module Type-A Blank Cover
- ASR 900 Route Switch Processor Type-A Blank Cover
- ASR 900 Power Supply Blank Cover
- ASR 900 Route Switch Processor 3, 400G, XL Scale, non-wide
- SP AR HW 24X7X4 ASR 900 Route Switch Processor 3, 400G,
- High performance fan tray w/o filter for the ASR 903 chassis
- ASR 900 1200W DC Power Supply
Feature | Description |
Physical specifications | Height: 5.22 in. (132.6 mm) - 3RU |
Width: 17.44 in. (443 mm) | |
Depth: 9.22 in. (234.2 mm) | |
Weight: | |
● 34.17 lb (15.5 kg) with two RSPs, two DC power supplies, and loaded with a typical combination of interface module cards | |
● 11.2 lb (5.1 kg) for an empty chassis | |
● 38 lb shipment weight | |
Rack mounts | ETSI rack mount kit |
19 in. rack mount kit | |
23 in. rack mount kit | |
Power supplies | 2 power supply slots |
Interface modules | 6 interface module slots |
Route switch processors | 2 RSP slots |
Fan tray | 1 fan tray with fan redundancy |
4 dry contact input alarms on the fan tray | |
Air flow | Side-to-side airflow; inlet on the right side, outlet on the left side when looking from the front |
Power supplies | Up to 2 power supplies (AC or DC) |
Modules operate in load-share mode | |
System can operate on a single power supply and supports mixing of one AC and one DC power supplies in a single chassis. | |
Power consumption | Maximum input power 1350W (including loss). This is equivalent to 4600 BTU per hr |
AC input voltage and frequency | Voltage range: 85 to 264 VAC, nominal 115 to 230 VAC |
Frequency Range: 47 to 63 Hz, nominal 50 to 60 Hz | |
DC input voltage | For 550W DC power supply, voltage range: 19.2V to 72V DC, nominal +24V DC, -48V/–60V DC. |
For 1200W DC power supply, voltage range: –40.8V to –72V DC, nominal –48V/–60V DC | |
Safety and compliance | |
Safety | ● UL 60950-1, 2nd edition |
● CAN/CSA C22.2 No. 60950-1-07 2nd edition | |
● IEC 60950-1, 2nd edition | |
● EN 60950-1, 2nd edition | |
● AS/NZS 60950.1:2003 | |
Electromagnetic | ● FCC CFR47 Part 15 Class A |
Immunity compliance | ● EN 300 386 |
● EN 61000-6-1 | |
● EN 50082-1 | |
● CISPR24 | |
● EN 55024 | |
● KN 24 | |
● EN 50121-4 | |
● EN/KN 61000-4-2 to EN/KN 61000-4-6 | |
● EN/KN 61000-4-8 | |
● EN/KN 61000-4-11 | |
Emissions compliance | ● EN55022, class A |
● CISPR22, class A | |
● ICES-003, class A | |
● EN 300 386, class A | |
● VCCI, class A | |
● KN22, class A | |
● EN61000-3-2 to EN61000-3-3 | |
Power substation system compliance | ● IEC-61850-3 (2002) (Cisco ASR 903) |
● IEEE1613 (2009) (Cisco ASR 903) | |
● IEC 60870-2-2 Am Class (Cisco ASR 907) and IEC 60870-2-2 Bm Class (Cisco ASR 902 / Cisco ASR 903) |
We Also Recommend
Invalid password
Enter